Apparently it’s been abandoned / empty for quite some time? Or is that seasonal?
It's in transition. Original owners sold it around 2022. I think it was open last year with new owners. Not sure if it bailed again before this mess. To be honest, I don't drive past it often in winter. I thought it was always seasonal.Apparently it’s been abandoned / empty for quite some time? Or is that seasonal?
I think the collapse was the historic store that was not in use.![]()
Muskoka Store reopens with nostalgic twist one year after fire
A beloved community staple in cottage country is finally reopening after a destructive fire forced it to shutter its doors last spring.www.ctvnews.ca
Appears there was a fire sometime in the last few years and they reopened in an adjacent property. So was this the new store or the old fire damaged one? If the fire damaged one maybe the roof was compromised from the fire? If the new location, well that is just really bad luck.
Wires would still be protected with the original 40 amp breaker. I wouldn't change it to 50 amp.I’m not an electrician but if specs are [emoji6][emoji[emoji6
]
[emoji6
]] and your running it on
[emoji[emoji6
]
[emoji6
]] , the wire could be undersized? You’re leaning into a potential fire hazard of your own making .
And yes. If reviews are to be believed you would only cook on open fire in the yard .
Sent from my iPhone using GTAMotorcycle.com
The chance you blow a breaker on a stove is minimal. As you said, the max amperage assumes every burner and oven is on at the same time. Even if you are using all the burners, most of them will be turned way down.Electrical question.
Looking at replacing a 32 year old Jenn air range. Preference is induction. Location is wired for 40 amp but I'm seeing some higher end ranges are specked for 50 amps. Changing out cable isn't an option. Would doing this result in regular breaker trips or would trips only happen if oven was on with all 4 burners cranked up? This would likely never happen.
Side note. Reading reviews of any appliance would result in never purchasing any of them.![]()
Check the gauge of wire it may already be sufficient for 50 amps (#6) but like others said it is unlikely you would trip the 40 amp breaker unless you turn everything on... Don't swap out to a 50 amp breaker unless the wiring can handle it.Electrical question.
Looking at replacing a 32 year old Jenn air range. Preference is induction. Location is wired for 40 amp but I'm seeing some higher end ranges are specked for 50 amps. Changing out cable isn't an option. Would doing this result in regular breaker trips or would trips only happen if oven was on with all 4 burners cranked up? This would likely never happen.
Side note. Reading reviews of any appliance would result in never purchasing any of them.![]()
Plug will match. Wiring is 4 wire awg 8. House is same age as Jenn Air. 32 years.The chance you blow a breaker on a stove is minimal. As you said, the max amperage assumes every burner and oven is on at the same time. Even if you are using all the burners, most of them will be turned way down.
Now, what is the wiring situation? Does stove come with a different plug? If you start rewiring to plug high draw appliances into low-draw receptacles, I don't think warranty or your home insurance will like you. If the plug is the same, I would just go for it. When I installed it, I would check draw under full load for peace of mind (or to give me an idea of any limitations that I may have).
Understood. ThanksCheck the gauge of wire it may already be sufficient for 50 amps (#6) but like others said it is unlikely you would trip the 40 amp breaker unless you turn everything on... Don't swap out to a 50 amp breaker unless the wiring can handle it.
Also make sure the current wiring is grounded. You are likely fine age wise but in the olden days they did not run a separate ground to the stove. Make sure the pug is four prong and not three. What you want to see is a NEMA 14-50....
View attachment 72732
It's hard to tell from pictures. My eyeball says 8 but I could be wrong. Look for marking or measure OD and check vs standard dimensions. In first pic it looks like one strand of the red may be cut off at the edge of the insulationI had a look. Looks like #6 to me ?
![]()
![]()
Sent from my iPhone using Tapatalk
I'm satisfied its #8It's hard to tell from pictures. My eyeball says 8 but I could be wrong. Look for marking or measure OD and check vs standard dimensions. In first pic it looks like one strand of the red may be cut off at the edge of the insulation
Breaker above it looks like 30A with 12ga? It's possible for some uses (like an air compressor) but not typical.